3M™ Cold Shrink Connector Insulators WF Series are open-ended, tubular, rubber sleeves which are factory expanded and assembled onto a removable core. The core is removed after the tube has been positioned over an inline connection, terminal lug, etc., allowing the tube to shrink and form a water-resistant seal. A variety of sizes cover a range of 1000/2000 volt cable.
3M™ Cold Shrink Connector Insulators WF Series are open-ended, tubular, rubber sleeves which are factory expanded and assembled onto a removable core. The core is removed after the tube has been positioned over an inline connection, terminal lug, etc., allowing the tube to shrink and form a water-resistant seal. The insulating tube is made of EPDM rubber, which contains no chlorides or sulfides. A variety of diameter sizes will cover a range of 1000/2000 volt cable from #4 AWG through 2000 kcmil copper conductors and #4 AWG through 1500 kcmil aluminium conductors. To extend the useful life of this product in applications which are continuously exposed to high levels of ultra-violet radiation, overwrap with Scotch® Super 33+™ Vinyl Electrical Tape or Scotch® Self-Fusing Silicone Rubber Electrical Tape 70.
Brands | 3M™ |
Cable Insulation Outside Diameter Range | 0.62-1.18 in, 1.00-1.94 in, 0.35-0.56 in, 0.45-0.82 in, 0.88-1.63 in |
Cable Insulation Outside Diameter Range (Metric) | 23,3 - 42,0 mm, 15.9 - 30.0 mm, 25.4-49.3 mm, 8.9-14.2 mm, 11.4-20.8 mm |
Cable Type | Low Voltage Single Conductor Insulated Cable |
Case Quantity | 10 |
Conductor Sizes (Imperial) | 4-2 AWG, 1-2/0 AWG, 3/0 AWG-250 kcmil, 350-500 kcmil, 600-750 kcmil (Al) 600-1000 kcmil (Cu) |
Insulation O.D. Range | 0.62-1.18 in, 1.00-1.94 in, 0.35-0.56 in, 0.45-0.82 in, 0.88-1.63 in |
Insulation O.D. Range (Metric) | 25.4-49.3 mm, 11.4-20.8 mm, 8.9-14.2 mm, 15.7-30.1 mm, 22.4-41.4 mm |
Material | EPDM Rubber |
Maximum Conductor Size (Imperial) | 2 AWG, 2/0 AWG, 250 kcmil, 500 kcmil, 750 kcmil (Aluminum), 1000 kcmil (Copper) |
Maximum Conductor Size (Metric) | 35 mm², 70 mm², 120 mm², 240 mm², 400 mm² (Aluminum), 500 mm² (Copper) |
Maximum Operating Temperature (Celsius) | 90 ℃ |
Maximum Operating Temperature (Fahrenheit) | 194 ℉ |
Maximum Operating Voltage | 2000 Volt |
Minimum Conductor Size (Imperial) | 1 AWG, 4 AWG, 3/0 AWG, 350 kcmil, 600 kcmil (Copper), 600 kcmil (Aluminum) |
Minimum Conductor Size (Metric) | 25 mm², 50 mm², 95 mm², 185 mm², 300 mm² (Aluminum), 300 mm² (Copper) |
Minimum Operating Temperature (Celsius) | -40 ℃ |
Minimum Operating Temperature (Fahrenheit) | -40 ℉ |
Number of Conductors | 1 |
Voltage | 2000 V |