3M™ 5411R Series Molded Rubber QS II Splice Kit is a 15kV 1 piece inline splice perfect to repair damaged cables. It is suitable to use on 15kV jacketed concentric neutral (JCN) or concentric neutral (CN) cables with copper or aluminum conductors. Its elongated design ensures the easy removal of damaged cables up to 6 inches.
3M™ 5411R Series QS II Splice Kit includes an EPDM molded rubber splice body, a packet of silicone grease and an instruction sheet. It replaces up to 6 inches of damaged cable, thereby eliminating the need to splice in a new section of cable with 2 separate splices. It is suitable to use on cables that can withstand a maximum temperature of 90 °C. The splice is molded from specially formulated, peroxide cured EPDM rubbers to provide physical protection. Connectors bridge the gap where the damaged cable is removed. The kit meets the requirements of IEEE 404 standards.
Cable Shielding | Concentric Neutral (CN), Jacketed Concentric Neutral (JCN) |
Case Quantity | 1 |
Connector Included | CIR-2, CIR-1/0, CIR-2/0, CIR-21, CIR-22, CIR-3/0, CIR-4/0, CIR-1/0 and two 10002, None |
Insulation O.D. Range | 0.637 - 0.900 Inch, 0.870 -1.055 Inch |
Insulation Outer Diameter (Imperial) | 0.63 in, 0.64 in, 0.65 in, 0.66 in, 0.67 in, 0.68 in, 0.69 in, 0.7 in, 0.71 in, 0.72 in, 0.73 in, 0.74 in, 0.75 in, 0.76 in, 0.77 in, 0.78 in, 0.79 in, 0.8 in, 0.81 in, 0.82 in, 0.83 in, 0.84 in, 0.85 in, 0.86 in, 0.87 in, 0.88 in, 0.89 in, 0.9 in, 0.91 in, 0.92 in, 0.93 in, 0.94 in, 0.95 in, 0.96 in, 0.97 in, 0.98 in, 0.99 in, 1 in, 1.01 in, 1.02 in, 1.03 in, 1.04 in, 1.05 in, 1.06 in |
Insulation Outer Diameter (Metric) | 16 mm, 16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm |
Insulation Outside Diameter Range | 0.637 - 0.900 Inch, 0.870 - 1.055 Inch |
Insulation Outside Diameter Range (Metric) | 16.3 - 22.9 mm, 22.1 - 26.9 mm |
Maximum Conductor Size (Imperial) | 2 AWG (Stranded), 4 AWG (Stranded), 1/0 AWG (Stranded), 2/0 AWG (Stranded), 3/0 AWG (Stranded), 4/0 AWG (Stranded) |
Maximum Conductor Size (Metric) | 25 mm² (Stranded), 35 mm² (Stranded), 50 mm² (Stranded), 50 mm² (Solid), 70 mm² (Stranded), 95 mm² (Stranded), 120 mm² (Stranded) |
Number of Conductors | 1 |
Operating Voltage | 15 kV |
Product Series | 5411R & 5412R Series |
Product Type | Inline Repair |
Splice Type | Inline Repair |
Voltage | 25/28 kV |
Safety Data Sheets
Document Number: MSDS_1055912_US_EN
(PDF)
Safety Data Sheets
Document Number: MSDS_2631596_US_EN
(PDF)
3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use. Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice. Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage. For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.