3M™ Bus Bar Heat Shrink Tubing BBI is a flame retardant tubing that provides reliable protection and insulation for 5 to 35 kV rated applications. The cross linked polyolefin construction is split and solvent resistant while offering good tracking resistance. It offers a tight fit for rectangular, square or round bus bars.
3M™ Bus Bar Heat Shrink Tubing BBI is made of a specially formulated cross-linked polyolefin. The tubing is colored orange-red. The material has high resistance to splitting, good solvent resistance and excellent tracking resistance properties. The tubing shrinks easily with industry standard methods, forming an aesthetically appealing insulation cover. The tubing meets the requirements of ANSI/IEEE Standard C37.20. The standard tubing lengths are 6.1 m (20') and 15.2 m (50').
Brands | 3M™ |
Expanded Wall Thickness | 0.043 in, 0.046 in, 0.048 in, 0.049 in, 0.054 in, 0.059 in |
Flame Retardant | Yes |
Halogen Free | No, Yes |
Heat Shrink Type | Heavy-Duty Heat Shrink Tubing |
Inner Diameter After Shrink (Imperial) | 0.043 in, 0.054 in, 0.128 in, 1.024 in, 3.28 in, 4.53 in, 5.43 in, 6.669 in, 7.571 in, 8.28 in, 10.29 in, 15.43 in |
Inner Diameter After Shrink (Metric) | 2.04 cm², 3.23 mm, 3.78 mm, 8.331 mm, 26 mm, 26.137 mm, 39.18 mm, 115 mm, 137.9 mm, 169.4 mm, 192.3 cm², 210 mm, 261.4 cm² |
Inner Diameter Before Shrink (Imperial) | 0.114 in, 0.127 in, 2.362 in, 3.78 in, 5.57 in, 8.86 in, 10.28 in, 10.858 in, 12.858 in, 13 in, 16.43 in, 24.14 in |
Inner Diameter Before Shrink (Metric) | 5.3 cm², 8.83 mm, 14.148 mm, 41.732 mm, 60 mm, 61.32 mm, 96 mm, 225 mm, 261 mm, 275.8 mm, 326.6 cm², 330 mm, 417.3 cm² |
Material | Cross-linked Polyolefin, Polyolefin |
Maximum Operating Temperature (Celsius) | 110 ℃ |
Maximum Operating Temperature (Fahrenheit) | 230 ℉ |
Maximum Recovered Tubing I. D. | 1.01 in, 1.67 in, 2.04 in, 2.33 in, 2.55 in, 3.18 in, 3.78 in, 4.53 in |
Minimum Expanded Tubing I. D. | 2.38 in, 4.35 in, 5.3 in, 5.9 in, 6.78 in, 8.25 in, 8.83 in, 10.28 in |
Model | Heat-shrink |
Operating Temperature (Celsius) | -55 °C to 110 °C |
Operating Temperature Range (Celsius) | -55 °C to 110 °C |
Operating Temperature Range (Fahrenheit) | -67 °F to 230 °F |
Outside Diameter (Bar Circumference) | 10.29 - 16.43 inch, 3.28 - 5.57 inch, 8.28 - 13.00 inch, 12.29 - 19.23 inch, 15.43 - 24.14 inch, 7.57 - 12.86 inch, 5.43 - 8.86 inch, 6.67 - 10.86 inch |
Product Color | Red, Orange |
Product Type | Bus Bar Tubing |
Recovered Wall Thickness | 0.113 in, 0.114 in, 0.117 in, 0.127 in, 0.128 in, 0.13 in, 0.138 in |
Rectangular Size | (4 x 1/4) to (4 x 3/4) Inch (for 35 kV), (5 x 1/4) to (5 x 3/4) Inch (for 35 kV), (6 x 1/4) to (6 x 3/4) Inch (for 35 kV), (8 x 1/4) to (8 x 3/4) Inch (for 35 kV), (3 x 5/8) to (5 x 3/4) Inch (for 5 kV, 8 kV, 15 kV, 25 kV), (4 x 1/4) to (6 x 3/4) Inch (for 5 kV, 8 kV, 15 kV, 25 kV), (5 x 1/4) to (8 x 3/8) Inch (for 5 kV, 8 kV, 15 kV, 25 kV), (6 x 1/4) to (9 x 3/4) Inch (for 5 kV, 8 kV, 15 kV, 25 kV), (8 X 1/4) to (10 x 3/4) Inch (for 5 kV, 8 kV, 15 kV, 25 kV), (2-1/2 x 3/8) to (4 x 3/4) Inch (for 5 kV, 8 kV, 15 kV, 25 kV), (3-1/2 x 1/2) to (6 x 3/4) Inch (for 5 kV, 8 kV, 15 kV, 25 kV), (1-1/2 x 1/4) to (2-1/2 x 1/2) Inch (5 kV, 8 kV, 15 kV, 25 kV) |
Relaxed Tube Length (Metric) | 6.1 m |
Round Size (Diameter) | 8 kV, 15 kV), 4 to 6-1/8 Inch ( for 5 kV, 5 to 7-5/8 Inch (for 5 kV, 4 to 4-7/8 Inch (for 25 kV), 4 - 4-7/8 Inch (for 35 kV), 5 to 5-1/4 Inch (for 35 kV), 5 to 6-1/4 Inch (for 25 kV), See Sizing Chart on Data Sheet |
Shape | Rectangular, Square, Round |
Shrink Ratio | 1.5 : 1, 2:1, 3:1, Variable |
Solution | constructionbus |
Splice Type | Heat Shrink |
Square Size | (3 x 3) Inch (for 25 kV), (5 x 5) Inch (for 25 kV), 2 x 2 Inch (for 5 kV, 8 kV, 15 kV), (2-1/2 x 2-1/2) Inch (for 25 kV), (3 x 3) to (4 x 4) Inch (for 5 kV, 8 kV, 15 kV), (5 x 5) to (6 x 6) Inch (for 5 kV, 8 kV, 15 kV), (3-1/2 x 3-1/2) to (4 x 4) Inch (for 25 kV), (1 x 1) to (1-1/2 x 1-1/2) Inch (for 5 kV, 8 kV, 15 kV), (2-1/2 x 2-1/2) to (3 x 3) Inch (for 5 kV, 8 kV, 15 kV), (2 x 2) to (2-1/2 x 2 1/2) Inch (for 5 kV, 8 kV, 15 kV), (3-1/2 x 3-1/2) to (5 x 5) Inch (for 5 kV, 8 kV, 15 kV), 10.29 - 16.43 inch OD (for 35 kV), 3.28 - 5.57 inch O.D. (for 25kV), 8.28 - 13.00 inch OD (for 35 kV), 12.29 - 19.23 inch OD (for 35 kV), 15.43 - 16.86 inch OD (for 35 kV), 7.57 - 12.86 inch OD (for 25 kV), 5.43 - 8.86 inch OD (for 25 kV), 6.67 - 10.86 inch OD (for 25 kV) |
UL Approval | No |
Units per Case | 1.0 |
Voltage | 5 kV, 8 kV, 15 kV, 25 kV, 35 kV |
With Inner Glue | No |
Overall Length (Imperial) | 20 ft, 50 ft |
Overall Length (Metric) | 6.1 m, 15.2 m, 15.24 m |
Regulatory Data Sheet
Document Number: MSDS_0663740_US_EN_RDS
(PDF)
Your form was submitted successfully.
An error has occurred while submitting. Please try again later...
3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use. Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice. Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage. For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.