3M™ Heat Shrink Cable Breakout Boot 2 insulates and seals cable breakouts in multi conductor armored or sheathed cables. This heavy duty boot offers good electrical and mechanical protection. The cross linked, MIL I 81765 1 qualified polyolefin construction is semi rigid and flame retardant.
3M™ Heat Shrink Breakout Boot has an internal coating of adhesive that ensures reliable environmental sealing of cable breakouts in cables and conduit ends. RoHS 2011/65/EU Compliant.
Brands | 3M™ |
Cable End Expanded | 0.8 in, 0.9 in, 1.2 in, 1.25 in, 1.5 in, 1.7 in, 1.75 in, 1.9 in, 2.35 in, 2.36 in, 2.39 in, 2.4 in, 2.65 in, 3 in, 3.2 in, 4.9 in, 5.25 in |
Cable End Recovered | 0.36 in, 0.37 in, 0.43 in, 0.5 in, 0.6 in, 0.69 in, 0.8 in, 0.9 in, 0.96 in, 0.98 in, 1 in, 1.4 in, 1.45 in, 1.9 in, 2 in, 2.32 in, 3 in |
Cable Insulation Outside Diameter Range | 0.87-1.06 in |
Cable Insulation Outside Diameter Range (Metric) | 22.1-26.8 mm |
Cable Shielding | Concentric Neutral (CN), Jacketed Concentric Neutral (JCN) |
Conductor Legs Expanded | 0.28 in, 0.33 in, 0.5 in, 0.65 in, 0.75 in, 0.79 in, 0.8 in, 0.82 in, 1 in, 1.18 in, 1.2 in, 1.25 in, 1.35 in, 1.4 in, 1.45 in, 2 in |
Conductor Legs Recovered | 0.11 in, 0.12 in, 0.16 in, 0.17 in, 0.18 in, 0.19 in, 0.28 in, 0.29 in, 0.3 in, 0.35 in, 0.5 in, 0.53 in, 0.55 in, 0.75 in, 1 in |
Connector Included | CIR-1/0 |
Dielectric Strength (V/mil) | 10 kV / mm |
Flame Retardant | Yes |
Heat Shrink Type | Heat Shrink Molded Shapes |
Indoor/Outdoor | Both |
Inner Diameter After Shrink (Imperial) | 0.11 in, 0.12 in, 0.16 in, 0.17 in, 0.18 in, 0.19 in, 0.28 in, 0.29 in, 0.3 in, 0.35 in, 0.5 in, 0.53 in, 0.55 mm, 0.75 in, 1 in |
Inner Diameter After Shrink (Metric) | 2.8 mm, 3.1 mm, 4.1 mm, 4.3 mm, 4.6 mm, 4.8 mm, 7.1 mm, 7.4 mm, 7.6 mm, 8.9 mm, 12.7 mm, 13.5 mm, 14 mm, 19.1 mm, 25.4 mm |
Inner Diameter Before Shrink (Imperial) | 0.28 in, 0.33 in, 0.5 in, 0.65 in, 0.75 in, 0.79 in, 0.8 in, 0.82 in, 1 in, 1.18 in, 1.2 in, 1.25 in, 1.35 in, 1.4 in, 1.45 in, 2 in |
Inner Diameter Before Shrink (Metric) | 7.1 mm, 8.4 mm, 12.7 mm, 16.5 mm, 19.1 mm, 20.1 mm, 20.3 mm, 20.8 mm, 25.4 mm, 30 mm, 30.5 mm, 31.8 mm, 34.33 mm, 35.6 mm, 36.8 mm, 50.8 mm |
Lug/Stem Connector Included in Kit | No |
Material | Semi-rigid, Flame Retardant Polyolefin |
Maximum Operating Temperature (Celsius) | 135 ℃ |
Minimum Shrink Temperature (Celsius) | 120 ℃ |
Model | Cold-shrink |
Number of Conductors | 1 |
Number of Outlets | 2,3,4,5,6 |
Operating Temperature (Celsius) | -30 up to +135°C |
Outer Diameter After Shrink (Imperial) | 0.36 in, 0.37 in, 0.43 in, 0.5 in, 0.69 in, 0.8 in, 0.9 in, 0.96 in, 0.98 in, 1 in, 1.4 in, 1.45 in, 1.5 in, 2 in, 2.32 in, 3 in, 15.2 in |
Outer Diameter After Shrink (Metric) | 0.9 mm, 9.1 mm, 9.4 mm, 10.9 mm, 12.7 mm, 17.5 mm, 20.3 mm, 22.9 mm, 24.4 mm, 24.9 mm, 25.4 mm, 35.6 mm, 36.8 mm, 38.1 mm, 50.8 mm, 58.9 mm, 76.2 mm, 322.6 mm |
Outer Diameter Before Shrink (Imperial) | 0.8 in, 0.9 in, 1.2 in, 1.25 in, 1.5 in, 1.7 in, 1.75 in, 1.9 in, 2.35 in, 2.36 in, 2.39 in, 2.4 in, 2.65 in, 3 in, 3.2 in, 4.9 in, 5.25 in, 30.5 in |
Outer Diameter Before Shrink (Metric) | 20.3 in, 22.9 mm, 30.5 mm, 31.8 mm, 38.1 mm, 43.2 mm, 44.5 mm, 48.3 mm, 59.7 mm, 59.9 mm, 60.7 mm, 61 mm, 67.3 mm, 76.2 mm, 81.3 mm, 124.5 mm, 133.4 mm, 386.1 mm |
Outlet Style | 2-Way, 3-Way, 4-Way, 5-Way, 6-Way |
Product Color | Black |
Product Series | 5450 Series |
Product Type | Cable & Wire Accessory, Splice |
Shrink Type | Heat Shrink |
Splice Type | Inline Repair |
Transition Type | 1 - 3 Breakout, 1 - 4 Breakout, 1-2 Breakout, 1-5 Breakout, 1-6 Breakout |
UV Resistant | Yes |
Units per Case | 1.0 |
Voltage | 25 kV, 28 kV |
Regulatory Data Sheet
Document Number: MSDS_3116852_US_EN_RDS
(PDF , 0B)
Your form was submitted successfully.
An error has occurred while submitting. Please try again later...
3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use. Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice. Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage. For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.