3M™ Molded Rubber QS-II Inline CN/JCN Cable Splice Kits 5450 Series

  • Options available
  • | Select product options for IDs.

Jacketing kit is required for JCN cable

Meets the requirements of IEEE 404 standards for cable joints

Computer design ensures a compact size and optimal distribution of the electrical field

View more details
icn_down_arrow
icn_down_arrow
icn_down_arrow
icn_down_arrow
icn_down_arrow
icn_down_arrow

Select product options

Details

Highlights
  • Jacketing kit is required for JCN cable
  • Meets the requirements of IEEE 404 standards for cable joints
  • Computer design ensures a compact size and optimal distribution of the electrical field
  • Designed for direct burial installations, aerial installations and submerged locations
  • Peroxide-cured EPDM rubber construction offers long term elastic memory

The 3M™ Molded Rubber QS-II Inline CN/JCN Cable Splice Kits 5450 Series kits are one-piece inline splices designed for use on 25/28 kV CN and JCNcable. Meets requirements of IEEE 404 for cable joints. The splice is a one-piece molded design made of specially formulated, peroxide cured EPDM rubbers. Each splice is production tested on CN cable to ensure reliability. Each kit makes one splice. Jacketing kit is needed for JCN cable. Connectors, unless specfied, are not included in the kit, and must be ordered separately. Refer to the index to find CI, CI-840 and CI-A series connectors. Note: Cable sizes shown below are for standard insulation thickness. Final determining factor is cable insulation O.D.

Typical properties

Application

Aerial Installations, For Inline Splicing, Submerged Locations, Direct-Burial Installations

Application/Industry

Utility

Cable Shielding

Concentric Neutral (CN), Jacketed Concentric Neutral (JCN)

Case Quantity

1

Conductor Material

Aluminum, Copper

Conductor Sizes (Imperial)

1 AWG, 1 AWG (Solid), 1 AWG (Stranded), 2 AWG, 2 AWG (Stranded), 1/0 AWG, 1/0 AWG (Solid), 1/0 AWG (Stranded), 2/0 AWG (Stranded), 3/0 AWG, 4/0 AWG, 2 to 2/0 AWG

Conductor Sizes (Metric)

35 mm² (Stranded), 50 mm² (Solid), 50 mm² (Stranded), 70 mm² (Stranded)

Connector Included

CI-1A, CI-2A, CI-1/0A, CI-2/0, CI-1/0-840, 20006, CI-21-840, None

Insulation Level

100%, 133%

Insulation O.D. Range

0.83 - 1.04 Inch, 0.775 - 0.90 Inch, 0.905 - 1.055 Inch, 1.00 - 1.15 Inch

Insulation Outer Diameter (Imperial)

0.83 in, 0.84 in, 0.85 in, 0.86 in, 0.87 in, 0.88 in, 0.89 in, 0.9 in, 0.91 in, 0.92 in, 0.93 in, 0.94 in, 0.95 in, 0.96 in, 0.97 in, 0.98 in, 0.99 in, 1 in, 1.01 in, 1.02 in, 1.03 in, 1.04 in, 1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in

Insulation Outer Diameter (Metric)

21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm

Insulation Outside Diameter Range

0.83 - 1.04 Inch, 0.775 - 0.90 Inch, 0.905 - 1.055 Inch, 1.00 - 1.15 Inch, 0.83 to 1.04 in

Insulation Outside Diameter Range (Metric)

21.1 - 26.4 mm, 19.7 - 22.9 mm, 23.0 - 26.8 mm, 25.4 - 29.2 mm, 21.1 to 26.4 mm

Kit Includes

(1) Instruction Sheet

Maximum Conductor Size (Imperial)

1 AWG, 2 AWG, 1/0 AWG, 2/0 AWG (Stranded), 2/0 AWG, 4/0 AWG

Maximum Conductor Size (Metric)

35 mm², 50 mm², 70 mm² (Stranded), 70 mm², 120 mm²

Minimum Conductor Size (Imperial)

2 AWG, 3/0 AWG

Minimum Conductor Size (Metric)

35 mm², 95 mm²

Number of Conductors

1

Operating Voltage

15 kV, 25 kV, 28 kV

Product Color

Back, White

Product Series

5450 Series, 5451A Series, 5411, 5411A & 5412 Series

Product Type

Inline, Splice

Splice Type

Inline

Typical Splice Length

14.4 in

Typical Splice Length (Metric)

366 mm

Voltage

25/28 kV

Resources

Safety Data Sheets

Document Number: MSDS_1055912_US_EN

(PDF)

Safety Data Sheets

Document Number: MSDS_1146232_US_EN

(PDF)

Manufacturing Origin: USA

The designation that a product is Manufactured in the USA means the product undergoes substantial transformation in one of our U.S. Manufacturing plants. Some products contain imported components.

Note: 3M products offered on a government contract that require country of origin representation must be certified by 3M Trade Compliance. Contact customer service at 800-245-3573 to request a certificate.
For industrial/occupational use only. Not for consumer sale or use.

3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use.  Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice.  Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage.  For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.