3M™ Cold Shrink QT-III 7640-S & 7650-S Series Termination Kit includes a skirted termination with a jumper wire-top insulator. It ensures a pliable, tight seal for jacketed concentric neutral and concentric neutral power cables. The conjunction of high dielectric-constant material and sealing compounds allows the termination to withstand voltages of 5 to 25/28 kV.
For polymeric power cable systems, use 3M™ Cold Shrink Termination QT-III. Our termination kits are designed for power cables with copper wire screen according to HD 620 (IEC 60502) and cover a wide application range. They feature a prefabricated one-piece cold shrink termination body, which allows fast and easy installation on a wide range of cable types and sizes, at temperatures ranging from -20 °C to +50 °C. No heat/flame or special tools are required for the installation. 3M™ Cold Shrink Termination QT-III meets and exceeds the requirements of European Standard CENELEC HD 629.1 and IEC 60502-4.
BIL | 95 kV, 150 kV, 200 kV |
Brands | 3M™ |
Breakout Boot | No, Yes |
Cable Insulation Outside Diameter Range | 1.53-1.81 in, 1.53-2.32 in, 0.70-0.92 in, 1.15-1.90 in, 1.15-1.98 in, 0.92-1.18 in |
Cable Insulation Outside Diameter Range (Metric) | 29,2-48,3 mm, 29,2-50,3 mm, 38.8-46.0mm, 38.9 - 58.9 mm, 17.8-23.4 mm, 23.4-30.0 mm |
Cable Shielding | Tape Shield, Wire Shield, UniShield®, Concentric Neutral (CN), Jacketed Concentric Neutral (JCN) |
Case Quantity | 1 |
Compatible Lug | QL2-A-4/0-600, QL2-A-350-750, QL2-A-500-1000, QL2-A-1000-1250 |
Conductor Sizes (Imperial) | 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil, 500 kcmil, 600 kcmil, 700 kcmil, 750 kcmil, 800 kcmil, 900 kcmil, 1000 kcmil, 1250 kcmil, 1500 kcmil, 1750 kcmil, 2000 kcmil |
Indoor/Outdoor | Outdoor Skirted, Indoor Non-skirted |
Insulation Level | 100%, 133% |
Insulation Outer Diameter (Imperial) | 0.701 in, 0.92 in, 0.94 in, 0.95 in, 0.96 in, 0.97 in, 0.98 in, 0.99 in, 1 in, 1.01 in, 1.02 in, 1.03 in, 1.04 in, 1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in, 1.16 in, 1.17 in, 1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in, 1.3 in, 1.31 in, 1.32 in, 1.33 in, 1.34 in, 1.35 in, 1.36 in, 1.37 in, 1.38 in, 1.39 in, 1.4 in, 1.41 in, 1.42 in, 1.43 in, 1.44 in, 1.45 in, 1.46 in, 1.47 in, 1.48 in, 1.49 in, 1.5 in, 1.51 in, 1.52 in, 1.53 in, 1.54 in, 1.55 in, 1.56 in, 1.57 in, 1.58 in, 1.59 in, 1.6 in, 1.61 in, 1.62 in, 1.63 in, 1.64 in, 1.65 in, 1.66 in, 1.67 in, 1.68 in, 1.69 in, 1.7 in, 1.71 in, 1.72 in, 1.73 in, 1.74 in, 1.75 in, 1.76 in, 1.77 in, 1.78 in, 1.79 in, 1.8 in, 1.81 in, 1.82 in, 1.83 in, 1.84 in, 1.85 in, 1.86 in, 1.87 in, 1.88 in, 1.89 in, 1.9 in, 1.91 in, 1.92 in, 1.93 in, 1.94 in, 1.95 in, 1.96 in, 1.97 in, 1.98 in, 1.99 in, 2 in, 2.01 in, 2.02 in, 2.03 in, 2.04 in, 2.05 in, 2.06 in, 2.07 in, 2.08 in, 2.09 in, 2.1 in, 2.11 in, 2.12 in, 2.13 in, 2.14 in, 2.15 in, 2.16 in, 2.17 in, 2.18 in, 2.19 in, 2.2 in, 2.21 in, 2.22 in, 2.23 in, 2.24 in, 2.25 in, 2.26 in, 2.27 in, 2.28 in, 2.29 in, 2.3 in, 2.31 in, 2.32 in |
Insulation Outer Diameter (Metric) | 17.8 mm |
Insulation Rejacketing | Yes, No |
Jacket Outside Diameter Range | 1.84-2.80 Inch |
Jacket Outside Diameter Range (Metric) | 46.8-71.1 mm |
Lug/Stem Connector Included in Kit | No |
Maximum Cable Outside Diameter | 5.40 in |
Maximum Cable Outside Diameter (Metric) | 137.2 mm |
Maximum Installed Length | 8.50 in, 13.25 in, 16.00 in, Termination only (not including RJS sleeving or Break-out boot: 21.5") |
Maximum Installed Length (Metric) | Termination only (not including RJS sleeving or Break-out boot: 546mm) |
Number of Conductors | 1 , 3 |
Number of Skirts | 4 , 8 |
Product Series | 3G, 3-RJS, 7690-S, 7600-3-W, 7650-T-150, 7640-S-TI, 7650-S-TI Series |
Voltage | 5 kV, 8 kV, 15 kV, 25 kV, 35 kV, 25/28 kV |
Safety Data Sheets
Document Number: MSDS_2651594_US_EN
(PDF)
Safety Data Sheets
Document Number: MSDS_2652436_US_EN
(PDF)
Safety Data Sheets
Document Number: MSDS_2654630_US_EN
(PDF)
Safety Data Sheets
Document Number: MSDS_2654440_US_EN
(PDF)
3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use. Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice. Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage. For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.