  5. 3M™ Curos™ Disinfecting Cap for Tego® Hemodialysis Connectors, CTG1-270

3M™ Curos™ Disinfecting Cap for Tego® Hemodialysis Connectors, CTG1-270

  • 3M ID 7100101992
  • UPC 50707387782035

Disinfects in one minute

Protects ports from contamination between access for up to seven days if not removed

Twists on easily and stays securely in place

View more details
Frequently viewed resources
PDF (1) Copy 26Safety Data Sheet (PDF)

Details

Highlights
  • Disinfects in one minute
  • Protects ports from contamination between access for up to seven days if not removed
  • Twists on easily and stays securely in place
  • White Curos™ caps for Tego® Hemodialysis Connectors are easily distinguished from green caps for dedicated use on the Tego® connectors
  • Design shields excess alcohol from entering lumen while providing sufficient flow of alcohol precisely where it is needed – on the exposed exterior of the male luer
  • In vitro testing shows effectiveness against the six microorganisms commonly associated with CLABSI: Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Pseudomonas aeruginosa, Candida glabrata, and Candida albicans
  • For single-use only

3M™ Curos™ Disinfecting Cap for Tego® Hemodialysis Connectors use 70% isopropyl alcohol to disinfect ports in one minute. They’re proven effective against Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Pseudomonas aeruginosa, Candida glabrata, and Candida albicans. They can be left in place to keep Tego® connectors clean and protected for up to seven days.

Suggested applications
  • Disinfect Tego® Hemodialysis Connectors before line access
  • Use only on Tego® Hemodialysis Connectors
  • Curos disinfecting port protectors may be used in the home or a healthcare facility
  • Three-year shelf life (please refer to product expiration date)
  • white glove removing a green Curos cap from a stain

    1. Peel foil tab or strip from the 3M™ Curos™ Disinfectant Port Protector cap.

  • white gloves removing the foil off the green Curos cap

    2. Once foil is removed, push and twist the Curos™ Disinfectant Port Protector onto the end of the needleless connector

  • white gloves inserting the green Curos cap onto a wireless connector

    3. The Curos disinfectant port protector must remain on the needleless connector for a minimum of one (1) minute and may remain on for seven (7) days (168 hours) or the duration of the intended use if not removed.

  • white gloves directly placing the green Curos cap onto the needleless connector

    4. A new Curos disinfectant port protector should be placed on the needleless connector after each use.

  • A picture of a green garbage bin

    5. Discard the Curos disinfectant port protector after use.

Specifications

Boxes per Case

8.0

Brands

Curos™

Catalog Number

CTG1-270R

Compatible Connector

Hemodialysis Connectors

Condition

I.V. Related

Latex

No

Product Colour

White

Shelf Life

3 yr

Units per Box

270.0

Units per Case

2160.0

Resources

Safety Data Sheets

Document Number: MSDS_3481835_CA_EN

(PDF)

Contact a Sales Rep

All fields are required.

  • Enter your 10-digit phone number. Numbers only (5555555555).
  • Select one...
  • Please confirm your information is correct.

  • Select one

3M will use the information to respond to your request and in accordance with our Privacy Policy.



3M takes your privacy seriously. 3M and its authorized third parties will use the information you provided in accordance with our Privacy Policy to send you communications, which may include promotions, product information and service offers.


Loading wheel

Thank you for contacting us! Logo
Thank you!

Your request has been submitted successfully. A representative will contact you shortly.

Sorry Logo

Sorry!

We can’t seem to complete your request. Please try again.